3.10 H: Terminal Functions
Setting Value
Function
111
!Down Command
114
!Fault Reset
116
!Motor 2 Selection
118
!Timer Function
119
!PID Disable
11A
!Accel/Decel Time Selection
2
11B
!Programming Lockout
11E
!Reference Sample Hold
130
!PID Integrator Reset
131
!PID Integrator Hold
132
!Multi-Step Speed Reference
4
134
!PID Soft Starter Disable
135
!PID Input (Error) Invert
13E
!PID Setpoint Selection 1
13F
!PID Setpoint Selection 2
144
!Add Offset Frequency 1
(d7-01)
145
!Add Offset Frequency 2
(d7-02)
146
!Add Offset Frequency 3
(d7-03)
147
!Node Setup (CANopen)
204
V/f
CL-V/f
OLV
CLV
AOLV
Set this function and 110 [!Up Command] together. Sets the Up command and Down command to use the two push button switches
to increase and decrease the drive frequency reference.
ON : Holds the current frequency reference.
OFF : Decreases the frequency reference.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to reset the current fault when the Run command is not active.
Note:
The drive ignores the fault reset command when the Run command is active. Remove the Run command before you try to reset
a fault.
V/f
CL-V/f
OLV
CLV
AOLV
Switches between motor 1 or motor 2. Switch the motor while the motor is stopped.
ON : Selects motor 1
OFF : Selects motor 2
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to start the timer function. Use this setting with H2-xx = 112 [!Timer Output].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to disable PID control with an external input when b5-01 = 1 to 8 [PID Function Setting = Enabled].
ON : PID control enabled
OFF : PID control disabled
V/f
CL-V/f
OLV
CLV
AOLV
Set this function and H1-xx = 107 [!Accel/Decel Time Selection 1] together. Sets the drive to use C1-01 to C1-08 [Acceleration/
Deceleration Times 1 to 4].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to prevent parameter changes when the terminal is OFF. You can continue to view parameter setting values when
the terminal is ON [Parameter Write Prohibit].
ON : Parameter Write Prohibit
OFF : Programming Lockout
V/f
CL-V/f
OLV
CLV
AOLV
Samples the analog frequency reference input to the terminals A1, A2, or A3, and continues operation at the sampled frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to reset and hold the PID control integral to 0 when the terminal deactivates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to hold the integral value of the PID control while the terminal deactivates.
V/f
CL-V/f
OLV
CLV
AOLV
Uses a combination of multi-step speed references 1, 2 and 3 (N.C.) to switch d1-09 to d1-16 [Reference 9 to 16].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the PID soft starter function.
ON : Enabled
OFF : Disable
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to turn the terminal ON and OFF to switch the PID input level (polarity).
V/f
CL-V/f
OLV
CLV
AOLV
Set this function and H1-xx = 13F [!PID Setpoint Selection 2] together. Sets the function to use the PID setpoint set in b5-58 to b5-
60 [PID setpoint2 to 4].
V/f
CL-V/f
OLV
CLV
AOLV
Set this function and H1-xx = 13E [!PID Setpoint Selection 1] together. Sets the function to use the PID setpoint set in b5-58 to b5-
60 [PID setpoint2 to 4].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-01 to the frequency reference when the terminal deactivates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-02 to the frequency reference when the terminal deactivates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-03 to the frequency reference when the terminal deactivates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function in CANopen communications to start the Node Setup function to set the drive node address from the host
controller.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM