YASKAWA GA800 Maintenance & Troubleshooting page 87

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

Code
Name
CPF18
Control Circuit Error
Note:
• Do a Fault Reset to clear the fault.
• Fault trace is not available for these faults.
Code
Name
CPF19
Control Circuit Error
Note:
• Do a Fault Reset to clear the fault.
• Fault trace is not available for these faults.
Code
Name
CPF20
Control Circuit Error
Note:
• Do a Fault Reset to clear the fault.
• Fault trace is not available for these faults.
Code
Name
CPF21
Control Circuit Error
Note:
• Do a Fault Reset to clear the fault.
• Fault trace is not available for these faults.
Code
Name
CPF22
Control Circuit Error
Note:
• Do a Fault Reset to clear the fault.
• Fault trace is not available for these faults.
Code
Name
CPF23
Control Circuit Error
Note:
• Do a Fault Reset to clear the fault.
• Fault trace is not available for these faults.
Code
Name
CPF24
Control Circuit Error (Drive Unit
Signal Fault)
Note:
• Do a Fault Reset to clear the fault.
• Fault trace is not available for these faults.
Code
Name
CPF26
Control Circuit Error
Note:
• Do a Fault Reset to clear the fault.
• Fault trace is not available for these faults.
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Causes
A drive hardware problem occurred.
Causes
A drive hardware problem occurred.
Causes
A drive hardware problem occurred.
Causes
A drive hardware problem occurred.
Causes
A drive hardware problem occurred.
Causes
A drive hardware problem occurred.
Causes
A drive hardware problem occurred.
Causes
A drive hardware problem occurred.
Possible Solutions
• Re-energize the drive.
• If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact Yaskawa
or your nearest sales representative.
Possible Solutions
• Re-energize the drive.
• If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact Yaskawa
or your nearest sales representative.
Possible Solutions
• Re-energize the drive.
• If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact Yaskawa
or your nearest sales representative.
Possible Solutions
• Re-energize the drive.
• If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact Yaskawa
or your nearest sales representative.
Possible Solutions
• Re-energize the drive.
• If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact Yaskawa
or your nearest sales representative.
Possible Solutions
• Re-energize the drive.
• If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact Yaskawa
or your nearest sales representative.
Possible Solutions
• Re-energize the drive.
• If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact Yaskawa
or your nearest sales representative.
Possible Solutions
• Re-energize the drive.
• If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact Yaskawa
or your nearest sales representative.
2.4 Fault
2
87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents