YASKAWA GA800 Maintenance & Troubleshooting page 407

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

A - Cutaway sections
A - Cutaway sections
Installing a Braking Unit Connection (CDBR-Type)
Remove the terminal cover before you connect the braking unit (CDBR-type) to the drive.
1.
Remove the screws on the terminal block cover and pull the terminal block cover away from the terminal
block. Pull the wiring cover away from the drive to remove the wiring cover after removing the terminal block
cover.
Note:
6-Phase/12-pulse drives (models: Txxx) do not have the wiring covers.
A - Terminal block cover
2.
Examine the signal from the wired terminal and use a diagonal-cutting pliers to remove areas of the wiring
cover cutaway section.
Note:
6-Phase/12-pulse drives (models: Txxx) do not have the wiring covers.
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
B - Use a diagonal-cutting pliers to clip this area.
Figure 5.77 Cutaway Sections
B - Use a diagonal-cutting pliers to clip this area.
Figure 5.78 Cutaway Sections
B - Wiring cover
Figure 5.79 Remove the Wiring Cover
5.9 Braking Resistor Installation
5
407