YASKAWA GA800 Maintenance & Troubleshooting page 244

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

3.13 o: Keypad-Related Settings
No.
Name
(Hex.)
o1-30
Custom Monitor 7
(11B3)
RUN
o1-31
Custom Monitor 8
(11B4)
RUN
o1-32
Custom Monitor 9
(11B5)
RUN
o1-33
Custom Monitor 10
(11B6)
RUN
o1-34
Custom Monitor 11
(11B7)
RUN
o1-35
Custom Monitor 12
(11B8)
RUN
o1-36
LCD Backlight Brightness
(11B9)
RUN
o1-37
LCD Backlight ON/OFF
Selection
(11BA)
RUN
o1-38
LCD Backlight Off-Delay
(11BB)
RUN
o1-39
Show Initial Setup Screen
(11BC)
RUN
o1-40
Home Screen Display
Selection
(11BD)
RUN
o1-41
1st Monitor Area Selection
(11C1)
RUN
o1-42
1st Monitor Area Setting
(11C2)
RUN
o1-43
2nd Monitor Area Selection
(11C3)
RUN
o1-44
2nd Monitor Area Setting
(11C4)
RUN
244
V/f
CL-V/f
OLV
CLV
AOLV
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the seventh line.
V/f
CL-V/f
OLV
CLV
AOLV
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the eighth line.
V/f
CL-V/f
OLV
CLV
AOLV
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the ninth line.
V/f
CL-V/f
OLV
CLV
AOLV
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the 10th line.
V/f
CL-V/f
OLV
CLV
AOLV
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the 11th line.
V/f
CL-V/f
OLV
CLV
AOLV
You can select a maximum of 12 monitors as user monitors and set them to parameters o1-24 to o1-
35. This parameter sets the user monitor to show on the 12th line.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the intensity of the LCD keypad backlight.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the automatic shut off function for the LCD backlight.
0 : OFF
1 : ON
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time until the LCD backlight automatically turns off.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to show the LCD keypad initial setup screen each time you energize the drive. This
parameter is only available with an LCD keypad.
0 : No
1 : Yes
V/f
CL-V/f
OLV
CLV
AOLV
Sets the monitor display mode for the Home screen. This parameter is only available with an LCD
keypad.
0 : Custom Monitor
1 : Bar Graph
2 : Analog Gauge
3 : Trend Plot
V/f
CL-V/f
OLV
CLV
AOLV
Sets the horizontal axis value used to display the monitor set in o1-24 [Custom Monitor 1] as a bar
graph. This parameter is only available with an LCD keypad.
0 : +/- Area ( - o1-42 ~ o1-42 )
1 : + Area ( 0 ~ o1-42 )
V/f
CL-V/f
OLV
CLV
AOLV
Sets the horizontal axis value used to display the monitor set in o1-24 [Custom Monitor 1] as a bar
graph. This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the horizontal range used to display the monitor set in o1-25 [Custom Monitor 2] as a bar
graph. This parameter is only available with an LCD keypad.
0 : +/- Area ( - o1-44 ~ o1-44 )
1 : + Area ( 0 ~ o1-44 )
V/f
CL-V/f
OLV
CLV
AOLV
Sets the horizontal axis value used to display the monitor set in o1-25 [Custom Monitor 2] as a bar
graph. This parameter is only available with an LCD keypad.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Default
(Range)
0
(0, 101 - 999)
0
(0, 101 - 999)
0
(0, 101 - 999)
0
(0, 101 - 999)
0
(0, 101 - 999)
0
(0, 101 - 999)
5
(1 - 5)
1
(0, 1)
60 s
(10 - 300 s)
1
(0, 1)
0
(0 - 3)
0
(0 - 1)
100.0%
(0.0 - 100.0%)
0
(0 - 1)
100.0%
(0.0 - 100.0%)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents