Setting Value
Function
93
DWEZ Digital Input 4
94
DWEZ Digital Input 5
95
DWEZ Digital Input 6
96
DWEZ Digital Input 7
97
DWEZ Digital Input 8
9F
DWEZ Disable
101
!LOCAL/REMOTE
Selection
102
!External Reference 1/2
Selection
103
!Multi-Step Speed Reference
1
104
!Multi-Step Speed Reference
2
105
!Multi-Step Speed Reference
3
106
!Jog Reference Selection
107
!Accel/Decel Time Selection
1
10A
!Accel/Decel Ramp Hold
10B
!Overheat Alarm (oH2)
10C
!Analog Terminal Enable
Selection
10D
!Ignore Speed Fdbk (V/f w/o
Enc)
10E
!ASR Integral Reset
110
!Up Command
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DriveWorksEZ digital input 4. Refer to the DriveWorksEZ online manual for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DriveWorksEZ digital input 5. Refer to the DriveWorksEZ online manual for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DriveWorksEZ digital input 6. Refer to the DriveWorksEZ online manual for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DriveWorksEZ digital input 7. Refer to the DriveWorksEZ online manual for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DriveWorksEZ digital input 8. Refer to the DriveWorksEZ online manual for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of the DriveWorksEZ program saved in the drive.
ON : Disabled
OFF : Enabled
Note:
Set A1-07 = 2 [DriveWorksEZ Function Selection = Enabled/Disabled wDigital Input] to use this function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets drive control for the keypad (LOCAL) or an external source (REMOTE).
ON : REMOTE
OFF : LOCAL
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to use Run command source 1/2 or Reference command source 1/2 when in REMOTE Mode.
ON : b1-01 = [Frequency Reference Selection 1], b1-02 [Run Command Selection 1]
OFF : b1-15 = [Frequency Reference Selection 2], b1-16 [Run Command Selection 2]
V/f
CL-V/f
OLV
CLV
AOLV
Uses a combination of multi-step speed references 1, 2 and 3 (N.C.) to set d1-01 to d1-08 [Multi-Step Speed Reference].
V/f
CL-V/f
OLV
CLV
AOLV
Uses a combination of multi-step speed references 1, 2 and 3 (N.C.) to set d1-01 to d1-08 [Multi-Step Speed Reference].
V/f
CL-V/f
OLV
CLV
AOLV
Uses a combination of multi-step speed references 1, 2 and 3 (N.C.) to set d1-01 to d1-08 [Multi-Step Speed Reference].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to use the JOG Frequency Reference (JOG command) set in d1-17 [Jog Reference]. The JOG Frequency Reference
(JOG command) overrides the d1-01 to d1-16 [References 1 to 16].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to use C1-01, C1-02 [Acceleration/Deceleration Time 1] or C1-03, C1-04 [Acceleration/Deceleration Time 2].
V/f
CL-V/f
OLV
CLV
AOLV
Momentarily pauses motor acceleration and deceleration when the terminal deactivates, retains the output frequency that was stored
in the drive at the time of the pause, and restarts motor operation.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to display an oH2 [Drive Overheat Warning] alarm when the input terminal deactivates. The alarm does not have an
effect on drive operation.
V/f
CL-V/f
OLV
CLV
AOLV
Enables and disables the terminal selected with the H3-14 [Analog Input Term Enable Select] function.
ON : Input to the terminal selected with H3-14 is disabled
OFF : Input to the terminal selected with H3-14 is enabled
V/f
CL-V/f
OLV
CLV
AOLV
When the terminal deactivates, the drive ignores the feedback control from the encoder and operates in V/f control. When the
terminal activates, the drive uses the feedback from the encoder to control the motor speed again.
ON : Speed feedback control enable (Closed Loop V/f Control)
OFF : Speed feedback control disable (V/f Control)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to reset the integral value and use PI control or P control for the speed control loop.
ON : PI control
OFF : P control
V/f
CL-V/f
OLV
CLV
AOLV
Set this function and 111 [! Down Command] together. Sets the Up command and Down command to use the two push button
switches to increase and decrease the drive frequency reference.
ON : Holds the current frequency reference.
OFF : Increases the frequency reference.
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM