5.3 Main Circuit Wiring
6-Phase/12-Pulse Rectification Connection Diagram
A - Branch circuit protection
B - Input reactor (optional)
C - Fuse
D - Delta to Wye transformer
Figure 5.32 Main Circuit Terminal Connections, Standard Hybrid 12-Pulse System
Note:
Refer to local codes for correct branch circuit protection (BCP) on the primary side of the 6-Phase/12-Pulse transformer.
376
E - Balancing reactor
F - Braking resistor (optional)
G - CDBR braking unit (optional)
H - Motor