3.4 A: Initialization Parameters
No.
Name
(Hex.)
A2-13
User Parameter 13
(0112)
A2-14
User Parameter 14
(0113)
A2-15
User Parameter 15
(0114)
A2-16
User Parameter 16
(0115)
A2-17
User Parameter 17
(0116)
A2-18
User Parameter 18
(0117)
A2-19
User Parameter 19
(0118)
A2-20
User Parameter 20
(0119)
A2-21
User Parameter 21
(011A)
A2-22
User Parameter 22
(011B)
A2-23
User Parameter 23
(011C)
A2-24
User Parameter 24
(011D)
A2-25
User Parameter 25
(011E)
A2-26
User Parameter 26
(011F)
A2-27
User Parameter 27
(0120)
154
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 13 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 14 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 15 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 16 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 17 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User Parameter Auto Selection =
Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 18 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User Parameter Auto Selection =
Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 19 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User Parameter Auto Selection =
Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 20 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User Parameter Auto Selection =
Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 21 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User Parameter Auto Selection =
Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 22 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User Parameter Auto Selection =
Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 23 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User Parameter Auto Selection =
Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 24 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User Parameter Auto Selection =
Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 25 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User Parameter Auto Selection =
Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 26 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User Parameter Auto Selection =
Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 27 of the [User Custom Parameters] under the
main menu. You can select a maximum of 32 parameters for the drive and set them to parameters A2-
01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User Parameter Auto Selection =
Disabled: Manual Entry Required].
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Default
(Range)
d1-17
(Determined by A1-06)
E1-01
(Determined by A1-06)
E1-03
(Determined by A1-06)
E1-04
(Determined by A1-06)
E1-05
(Determined by A1-06)
E1-06
(Determined by A1-06)
E1-09
(Determined by A1-06)
E1-13
(Determined by A1-06)
E2-01
(Determined by A1-06)
E2-04
(Determined by A1-06)
E2-11
(Determined by A1-06)
H4-02
(Determined by A1-06)
L1-01
(Determined by A1-06)
L3-04
(Determined by A1-06)
-
(Determined by A1-06)