YASKAWA GA800 Maintenance & Troubleshooting page 215

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

Setting Value
Function
117
Torque Detection 1 (N.O.)
118
Torque Detection 2 (N.C.)
119
Torque Detection 2 (N.O.)
11A
!During Reverse
11B
During Baseblock (N.O.)
11C
!Motor 2 Selected
11D
!During Regeneration
11E
!Executing Auto-Restart
11F
!Motor Overload Alarm
(oL1)
120
!Drive Overheat Pre-Alarm
(oH)
121
!Safe Torque OFF
122
!Mechanical Weakening
Detection
12F
!Maintenance Notification
130
!During Torque Limit
131
!During Speed Limit
132
!In Speed Limit During Trq
Ctrl
133
!Zero Servo Complete
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive detects overtorque or undertorque.
ON : The output current/torque exceeds the torque value set with L6-02 [Torque Detection Level 1], or the level has dropped and
remained in this state longer than the time set with L6-03 [Torque Detection Time 1].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects overtorque or undertorque.
OFF : The output current/torque exceeds the torque value set with L6-05 [Torque Detection Level 2], or the level has dropped and
remained in this state longer than the time set with L6-06 [Torque Detection Time 2].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive detects overtorque or undertorque.
ON : The output current/torque exceeds the torque value set with L6-05 [Torque Detection Level 2], or the level has dropped and
remained in this state longer than the time set with L6-06 [Torque Detection Time 2].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the motor operates in the reverse direction.
ON : The motor is operating in the forward direction or the motor stopped.
OFF : The motor is operating in the reverse direction.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates during baseblock. When the drive is in baseblock, the drive output transistor stops switching and does not
make DC bus voltage.
ON : During baseblock
OFF : The drive is not in baseblock.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when motor 2 is selected.
ON : Motor 1 Selection
OFF : Motor 2 Selection
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the motor is regenerating.
ON : Motor is operating or stopped.
OFF : Motor is regenerating.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the Auto Restart function is trying to restart after a fault.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the electronic thermal protection value of the motor overload protective function is a minimum of
90% of the detection level.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive heatsink temperature is at the level set with L8-02 [Overheat Alarm Level].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates (safety stop state) when the safety circuit and safety diagnosis circuit are operating correctly and when
terminals H1-HC and H2-HC are OFF (Open).
ON : Safety circuit fault or RUN/READY
OFF : Safety stop state
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects mechanical weakening.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when drive components are at their estimated maintenance period.
Tells you about the maintenance period for these items:
• IGBT
• Cooling Fan
• Capacitor
• Soft charge bypass relay
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the torque reference is the torque limit set with L7 parameters, H3-02, H3-06, or H3-10 [MFAI
Function Selection].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the speed limit is active.
V/f
CL-V/f
OLV
CLV
AOLV
The motor accelerates in the forward direction or the reverse direction after enabling torque control and the externally-input torque
reference is disproportionate to the load. The output terminal deactivates when this speed is not higher than a constant speed and the
motor speed is at the speed limit. This does not include operation when the drive is stopped.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when positioning in the range set with b9-02 [Zero Servo Completion Window] completes after sending the
Zero-Servo command.
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
3.10 H: Terminal Functions