1.1.4. CV Mode:
At Constant Voltage mode, the 3270 series Electronic Load will attempt to sink enough
current until the load input voltage reaches the programmed value (see Fig 1-9).
1.1.5. CP Mode:
At Constant Power mode, the 3270 series Electronic Load will attempt to sink load power
(load voltage * load current) in accordance with the programmed power. (See Fig 1-10).
Voltage Setting

Fig 1-9 Constant Voltage mode

Power Setting

Fig 1-10 Constant Power mode