146 PRODIGIT
Example Sequence
In this example, we will create a program based on following Figure.
The program repeats steps 1 to 8 two times. After repeating the sequence two times, the load is turned
off and the sequence ends.
Sequence Number Step Number
3
3
3
3
3
3
3
3
Creating the program
1. Setting the Load current level and store to state 1~8
2. Set the operation mode
Press the mode key to CC mode.
3. Set the range
Press RANGE key to force range 2
4. Press Load ON
5. Set the current value as step 1~8 and store to memory state 1~8
6. Press EDIT key of 3270 series mainframe
7. Press up/down key to select Edit Mode
8. Press sequence number 3 to edit the sequence
9. Press up/down key to memory state 1
10. Press ENTER key to confirm the sequence memory
11. Press up/down key to setting execution time
12. Press ENTER key to confirm the sequence step
13. Repeat 8~12 to setting step 1~8
14. Press SAVE key to confirm step 1~8
15. Press up/down key to 1 to repeat one times.
16. Press ENTER to confirm the repeat count.
Current Value
1
1A
2
5A
3
1A
4
5A
5
1A
6
10A
7
1A
8
0A
Execution Time(T1+T2)
200mS
200mS
400mS
400mS
200mS
200mS
200mS
200mS