INRUS ISTEP : setting the INRUS ISTEP, the Left 5 digit monitor display the
"INRUS" ,the right upper 5 digit monitor display the "ISTEP", and right lower
monitor display setting value, the unit is "A". Use the knob and button to set the
ISTEP current value, the setting range from 0.000 A to 75.000A.
INRUS TIME : setting the INRUS TIME, the Left 5 digit monitor display the
"INRUS" ,the right upper 5 digit monitor display the "TIME", and right lower monitor
display setting value, the unit is "ms". Use the knob and button to set the time, the
setting range from 0.1ms to the 100.0ms.
INRUS ISTOP : setting the INRUS ISTOP, the Left 5 digit monitor display the
"INRUS" ,the right upper 5 digit monitor display the "ISTOP", and right lower
monitor display setting value, the unit is "A". Use the knob and button to set the
ISTOP current value, the setting range from 0.000 A to 37.500A.
• The SURGE parameters setting:
Pressing the Item key once will cause the button to illuminate. The message
"SURGE PRESS START" will be shown across the displays.
Each press of the setting button moves the menu on one step. The Left and right
LCDs show the currently selected test parameter as text. The value is adjusted by
The rotary knob and can be read from the Right display during Setting.
The setting sequence is shown below:
SURGE PRESS START
SURGE FREQ
SURGE S1
SURGE T1
SURGE S2
SURGE T2
SURGE S3
SURGE T3
3270 Series Operation Manual 67