Prodigit 3270 Series Operation Manual page 125

Ac/dc high power electronic load
Table of Contents

Advertisement

116 PRODIGIT
4.7.5. MEASURE Measure the actual current and voltage value of Load
MEASure:CURRent?
Syntax:MEASure:CURRent{?}{;NL}
Purpose:Read the current which is loading of Load
Description:Read the five numbers of current meters, and the unit is Ampere (A)
MEASure:VOLTage?
Syntax:MEASure:VOLTage{?}{;NL}
Purpose:Read the voltage which is loading of Load
Description:Read the five numbers of current meters, and the unit is Voltage (V)
MEASure:POWer?
Syntax:MEASure:POWer{?}{;NL}
Purpose:Read the power which is loading of Load
Description:Read the five numbers of current meters, and the unit is Watt (W)
MEASure:VAR?
Syntax:MEASure:VAR {?}{;NL}
Purpose:Read the reactive power which is loading of Load.
Description:Read the reactive power which is loading of Load, Unit is Var.
MEASure:VA?
Syntax:MEASure:VA {?}{;NL}
Purpose:Read the apparent power which is loading of Load.
Description:Read the apparent power which is loading of Load, Unit is VA
MEASure:V_THD?
Syntax:MEASure:V_HD {?}{;NL}
Purpose:Read the Voltage harmonic distortion of the Load.
Description:Read the Voltage harmonic distortion of the Load.
MEASure:I_THD?
Syntax:MEASure:I_HD {?}{;NL}
Purpose:Read the current harmonic distortion of the Load.
Description:Read the current harmonic distortion of the Load.
MEASure:V_HARM?
Syntax: MEASure : V _HARM {?}{;NL}
Purpose:Read the Voltage harmonic distortion order of the Load.
Description:Read the Voltage harmonic distortion order of the Load.
MEASure:I_HARM?
Syntax:MEASure:I_HARM {?}{;NL}
Purpose:Read the current harmonic distortion order of the Load.
Description:Read the current harmonic distortion order of the Load.

Advertisement