3.5.1.10. Master 3ph Manual operation:
(3270 MASTER 3ph/SLAVE model the following is example)
PRESET setting: CC/LIN/CR/CV/CP Mode as Figure, CC setting 30A=Master
30A + Slave 1 30A+ Slave 2 30A, LIN setting 30A=Master 30A + Slave 1 30A+
Slave 2 30A, CR: 3.666Ω=Master=Slave 1=3.666Ω=Slave2=3.666Ω,
CP: 3300W=Master 3300W = Slave 1 3300W=Slave 2 3300W, CV: 100V=Master
110V= Slave 1=110V =Slave 2=110V.
Master 3ph
Display
Slave1
Display
Slave2
Display
Master 3ph
Display
Slave1
Display
Slave2
Display
3270 Series Operation Manual 79
Figure CC Set 30A
Figure LIN Set 30A