Non-L CC: setting the Non-L current point, the Left 5 digit monitor display the
"Non-L" ,the right upper 5 digit monitor display the "CC", and right lower monitor
display setting value, the unit is "A". The range is 0.001A to the full scale of the CC
mode specification.
Non-L PF: setting the PF, the Left 5 digit monitor display the "Non-L" ,the right
upper 5 digit monitor display the "PF", and right lower monitor display setting value,
The range is 0.01 ~ 1.00.
NL+CR Nonlinear plus CR test key function parameter setting:
Pressing the Item key once will cause the button to illuminate. The message
"NL+CR PRESS START" will be shown across the displays.
Each press of the setting button moves the menu on one step. The Left and right
LCDs show the currently selected test parameter as text. The value is adjusted by
The rotary knob and can be read from the Right display during Setting.
The setting sequence is shown below:
NL+CR PRESS START
NL+CR CC
NL+CR CR
NL+CR CC: setting the NL+CR CC current point, the Left 5 digit monitor display
the "NL+CR", the right upper 5 digit monitor display the "CC", and right lower
monitor display setting value, the unit is "A", use the knob and button to set the
Nonlinear CC current value, the range from 0.000A to full scale current of the CC
mode specification.