Prodigit 3270 Series Operation Manual page 36

Ac/dc high power electronic load
Table of Contents

Advertisement

Setting Mode:
The right display together with the rotary adjustment knob is used to set values.
The value changes according to the setting function that is active. The middle LCD
provides a text message to tell the user which part of the setting menu is active.
3.3.7.1.
PRESET mode. The value of the setting entered on the right display
Changes depending on the operating MODE that has been selected
• If CC mode is selected the right display provides setting in amps "A".
• If LIN mode is selected the right display provides setting in amps "A"
• If CR mode is selected the right display provides setting in ohms "Ω"
• If CP mode is selected the right display provides setting in watts "W".
• If CV mode is selected the right display provides setting in volts "V".
3.3.7.2.
LIMIT. Each press of the LIMIT button changes the middle LCD text. The
Sequence and the corresponding setting value shown on the bottom
Display is as follows:
V_Hi (left limit voltage) displays the set value in volts "V"
V_Lo (right limit voltage) displays the set value in volts "V"
I_Hi (left limit current) displays the set value in amps "A"
I_Lo (right limit current) displays the set value in amps "A"
W_Hi (left limit power) displays the set value in watts "W"
W_Lo (right limit power) displays the set value in watts "W"
VA_Hi (left limit power) displays the set value in VA "VA"
VA_Lo (right limit power) displays the set value in VA "VA"
OPL (right limit power) displays the set value in watts "W"
OCL (right limit power) displays the set value in amps "A"
NG displays whether the NG flag is set to "ON" or "OFF".
3.3.7.3.
CONFIG. Each press of the CONFIG button changes the right upper
LCD Text.
The sequence and the corresponding setting value shown on the bottom
Displays are as follows:
EXTIN can be set to「OFF」or 「ON」
SYNC can be set to「OFF」or 「ON」
LD ON
LDOFF
BW can be set to 1~15.
AVG can be set to 1, 2, 4,8,16.
CPRSP can be set to 0~7.
CYCLE can be set to 1~16.
3270 Series Operation Manual 27