104 PRODIGIT

4-5. The description of abbreviation

SP:Space, the ASCII code is 20 Hexadecimal.
;:Semicolon, Program line terminator, the ASCII code is OA Hexadecimal.
NL:New line, Program line terminator, the ASCII code is OA Hexadecimal.
NR2:Digits with decimal point. It can be accepted in the range and format of ###.#####.
For Example:
30.12345, 5.0
The description of GPIB programming command syntax.

4-6. Remote Control Command Language description

: The contents of the { } symbol must be used as a part or data of the GPIB
{ }
command, it cannot be omitted.
: The contents of the [ ] symbol indicts the command can be used or not. It
[ ]
depends on the testing application.
: This symbol means option. For example〝LOW|HIGH〞means it can only use
|
after send the GPIB command, the available command terminator characters
which can be accepted in 3270 Series mainframe is listed in Table 4-8.

4-7. Remote control command description

4.7.1. PRESET Set and Read the Default of Load
HARM
Syntax: [PRESet:] HARM{SP} {NR1} {;NL}
Purpose: Set and read the HARMONICS
Description: Set and read the HARMONICS
LIN
Syntax: [ PRESet:] LIN :AB {SP}{NR2}{;NL}
Purpose: Set and read the linear current.
Description:Set and read the linear current.
LOW or HIGH as the command, it can choose only one as the setting command.
:
Terminator
You have to send the program line terminator character
CR,LF WITH EOI

Table 4-8 GPIB COMMAND TERMINATOR

Semicolon〝;〞:
The semicolon〝;〞is a back-up command, the semicolon
allows you to combine command statement on one line to create command
message.
[ PRESet:] HARM{?} {;NL}
[ PRESet:] LIN :AB {?} {;NL}
LF
LF WITH EOI
CR,LF

Advertisement