Prodigit 3270 Series Operation Manual page 91

Ac/dc high power electronic load
Table of Contents

Advertisement

82 PRODIGIT
3.5.1.12. Master Mode operation except CC / CR / CV / CP MODE, The following functions
Will be disable.
• Recall/Store Disable.
• Short, OCP, OPP Disable.
• External I/O Disable
3.5.1.13. REMOTE operating: Master Mode can use the command as follows
SETTING PRESET NUMERIC COMMAND
MODE {SP} {CC│LIN│CR│CP} {;NL}
OCL{SP} {NR2} {;NL}
OPL{SP} {NR2} {;NL}
SENS {SP} {ON│OFF│1│0} {;│NL}
ON:ANG{SP} {NR2} {;NL}
OFF:ANG{SP} {NR2} {;NL}
CC CURR:{A B} {SP} {NR2}{;NL}
LIN:{A B} {SP} {NR2}{;NL}
CR RES:{A B} {SP} {NR2}{;NL}
CP:{A B} {SP} {NR2}{;NL}
MODE {SP} {CC│LIN│CR│CP} {;│NL}
LEV {SP} { A│B│0│1} {;│NL}
FREQ {SP} {AUTO│NR2} {;│NL}
PF {SP} {NR2} {;│NL}
CF {SP} {NR2} {;│NL}
LOAD {SP}{ON│OFF│1│0} {;│NL}
MEAS:CURR {?}{;NL}
MEAS:VOLT {?}{;NL}
MEAS:POW {?}{;NL}
MEAS:VA {?}{;NL}
MEAS: VAR {?}{;NL}
MEAS: PF {?}{;NL}
Master boost
Display
Slave 1
Display
Slave 2
Display
Figure CP Set 9900W
REMARK
0:OFF, 1:ON
0~359
0~359
1.4~5.0 ;1.3(TRAIL),1.2(