4.7.2. LIMIT Set and read the top and bottom of the Load judgment NG limit
[LIMit:]CURRent:{ HIGHLOW} or IHIL
Syntax: [LIMit]:CURRent:{ HIGHLOW}{SP}{ NR2 }{;NL}
[LIMit]:CURRent:{ HIGHLOW} {?}{;NL}
[IHIL]{SP}{NR2}{;NL}
[IHIL} ?{;NL}
Purpose:To set the upper/lower limit value of threshold current.
Description:This command is to set the lower limit value of threshold current. When
load sink current is lower than this lower limit value or higher than the
upper limit value, NG indicating light will come on to indicate 〝NO GOOD
〞.
[LIMit:]POWer:{ HIGHLOW} or WHWL
Syntax: [LIMit]:POWer:{ HIGHLOW}{SP}{ NR2 }{;NL}
[LIMit]:POWer:{ HIGHLOW} {?}{;NL}
[WHWL]{SP}{ NR2 }{;NL}
[WHWL]?{;NL}
Purpose:To set the upper/lower limit value of threshold power (W).
Description:This command is to set the upper/lower limit value of threshold power
(WATT). When power (WATT) is lower than this lower limit value or higher than
the upper limit value, NG indicating light will come on to indicate〝NO GOOD〞.
[LIMit:] VOLtage:{ HIGHLOW} or VHVL
Syntax: [LIMit] VOLtage:{ HIGHLOW}{SP}{ NR2 }{;NL}
[LIMit] VOLtage:{ HIGHLOW} {?}{;NL}
[VHVL]{SP}{ NR2 }{;NL}
[VHVL}?{;NL}
Purpose:To set the upper/lower limit value of threshold voltage.
Description:This command is to set the upper/lower limit value of threshold voltage.
When input voltage is lower than the lower limit value or higher than the upper
limit value, NG indicating light will come on to indicate〝NO GOOD〞.
SVHSVL
Syntax: [LIMit:] {SVHSVL}{SP}{ NR2 }{;NL}
[LIMit:] { SVHSVL} {?}{;NL}
Purpose:To set the upper/lower limit value of short current.
Description:This command is to set the upper/lower limit value of short current. When
short current is lower than the lower limit value or higher than the upper limit
value, NG indicating light will come on to indicate〝NO GOOD〞.
3270 Series Operation Manual 111