Restart The Device; Query Health Status; View Current Communication Protocol; Set Communication Protocol - Lightware MX8x8HDMI-PRO User Manual

Hide thumbs Also See for MX8x8HDMI-PRO:
Table of Contents

Advertisement

7.2.7. Restart the device

Description: The device can be restarted without unplugging power.
Command {RST}
Response (CPU_RESET...)
Explanation: The device reboots.

7.2.8. Query health status

Description: Internal voltages and measured temperature values are shown.
Command {ST}
Response (STAT●<DESC>)CrLf

7.2.9. View current communication protocol

Description: Shows the RS-232, TCP/IP communication protocol.
Command {P_?}
Response (CURRENT●PROTOCOL●=●
Explanation: The current communication protocol is Lightware protocol.
Legend:

7.2.10. Set communication protocol

Description: Internal voltages and measured temperature values are shown.
Command {P_<x>}
Response (PROTOCOL●#<x>●
Explanation: The communication protocol is set to Lightware protocol.

7.2.11. Count HDCP keys

Description: If there is an HDCP source on any input of the matrix, the matrix can ask the
source whether it can handle <num> piece of sink devices.
Command {:HDCPTEST<in>@<num>}
Response (HDCPTEST=SUCCESS)CrLf
Explanation: The source on the 2nd input can handle 8 HDCP sink devices.
Chapter 7. Programmers' reference
Format
(MX8x8DVI FRAME Ready!)
Format
Format
#<x>)CrLf
No.
1
2
Format
SELECTED!)CrLf
Format
MX8x8HDMI-Pro series
Example
 {RST}
 (CPU_RESET...)
 (MX8x8DVI FRAME Ready!)
Example
 {ST}
 (STAT 3.3V 5.0V 29V)
Example
 {p_?}
 (CONTROL PROTOCOL = #1)
Control protocol
Lightware protocol
P#2 protocol
Example
 {p_1}
 (PROTOCOL #1 SELECTED!)
Example
 {:hdcptest2@8}
 (HDCPTEST=SUCCESS)
User's manual
Page 49 / 81

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx8x8dvi-hdcp-pro

Table of Contents