Outrigger Cylinder Manifold Components - Gs-3232 - Terex Genie GS-1330m Service And Repair Manual

Hide thumbs Also See for Genie GS-1330m:
Table of Contents

Advertisement

Service and Repair Manual
Manifolds
5-10
Outrigger Cylinder Manifold Components – GS-3232
The outrigger function manifold is mounted behind an inspection door, at the battery side of the machine.
Note: 'alpha-numeric' callouts refer to corresponding notes on the electrical schematic.
Index No.
1
Solenoid valve, 2 position 2 way
2
Orifice Plug, 0.037 inch / 0,94 mm
3
Check Valve, pilot operated
4
Pressure transducer
Coil nut
Front Outrigger Cylinder
How to Install a Valve Cartridge
1
Dip the cartridge in clean oil to lube the O-rings.
2
Screw the cartridge in by hand until the top O-ring is met, then torque to specifications.
3
If required, install the valve coil(s) onto the valve stem. Install the coil nut onto the valve stem and
torque to specifications.
58
Description
GS
-30m • 32m • 30 • 32 • 46 • 55
Schematic Item
Function
Outriggers
CA, CB, CC, CD
extend / retract
CE
Outrigger retract
Retract flow
CF
Outrigger auto
CG
CA, CB, CC, CD
Rear Outrigger Cylinder
August 2021
Torque
25 ft-lbs / 34 Nm
20 ft-lbs / 27 Nm
control
16 ft-lbs / 21,7 Nm
level
4-5 ft-lbs / 5-7 Nm
Part No. 1309020GT

Hide quick links:

Advertisement

Table of Contents
loading