Service and Repair Manual
Scissor Components
Upper Lift Cylinder GS-4655
6 relief valve, (schematic item Q)
7 lift cylinder
8 connector fitting
9 solenoid valve, (schematic item DK)
10 orifice, (schematic item O)
156
Torque specifications
Solenoid valve, 2 position 2 way, N.C.
(schematic item DK)
Relief valve, (schematic item Q)
Coil nut
20 Remove the lifting device supporting the link
21 Connect the battery pack to the machine.
22 Turn the key switch to ground controls.
23 Press and hold the ground control scroll up
24 Pull out the red Emergency Stop button to the
25 Using the ground control menu buttons,
Note: The machine must be in Service Override
Mode to raise the platform. While in Service
Override Mode, only the GCON will operate with
limited functionality. The platform will raise a
predetermined amount of time and stop.
26 Raise the platform and rotate the safety arm
27 Fully lower the platform to the stowed
28 Calibrate the platform overload system. Refer
GS
-30m • 32m • 30 • 32 • 46 • 55
stack at the steer end of the machine.
and scroll down buttons.
on position at the ground controls.
navigate to Service Override Mode. Select
Service Override Mode.
to the stowed position.
position.
to Repair Procedure How to Calibrate the
Platform Overload System.
August 2021
20 ft-lbs
27 Nm
20 ft-lbs
27 Nm
5 ft-lbs
7 Nm
Part No. 1309020GT