Terex Genie GS-1330m Service And Repair Manual page 203

Hide thumbs Also See for Genie GS-1330m:
Table of Contents

Advertisement

August 2021
Type "HXXX" Faults, (continued)
DTC
Message on
Number
GCON LCD
H106:COILFAULT
H106:
DECK EXTEND:BAT-
H107:COILFAULT
H107:
DECK EXTEND:OPEN
H108:COILFAULT
H108:
DECK EXTEND:BAT+
H109:COILFAULT
H109:
DECK RETRACT:BAT-
H110:COILFAULT
H110:
DECK RETRACT:OPEN
H111:COILFAULT
H111:
DECK RETRACT:BAT+
H114:COILFAULT
H114:
DECK ENABLE:BAT+
H115:COILFAULT
H115:
DECK ENABLE
Part No. 1309020GT
Description
Short circuit of the platform extend
circuit to battery negative.
Open circuit in the platform extend
circuit.
Short circuit of the platform extend
circuit to battery positive.
Short circuit of the platform retract
circuit to battery negative.
Open circuit in the platform retract
circuit.
Short circuit of the platform retract
circuit to battery positive.
Short circuit of the platform enable
circuit to battery positive.
Short circuit of the platform enable
circuit.
GS
-30m • 32m • 30 • 32 • 46 • 55
Type "HXXX" Faults
Possible Causes
• Short circuit in PED harness.
• PED extend valve coil short circuit.
• GCON ECM.
• Open circuit in PED harness.
• PED extend valve coil open circuit.
• GCON ECM.
• Short circuit in PED harness.
• PED extend valve coil short circuit.
• GCON ECM.
• Short circuit in PED harness.
• PED retract valve coil short circuit.
• GCON ECM.
• Open circuit in PED harness.
• PED retract valve coil open circuit.
• GCON ECM.
• Short circuit in PED harness.
• PED retract valve coil short circuit.
• GCON ECM.
• Short circuit in PED harness.
• PED enable valve coil short circuit.
• GCON ECM.
• Short circuit in PED harness.
• GCON ECM.
Service and Repair Manual
Failure Mode
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
189

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents