Service and Repair Manual
Manifolds
GS-2032, GS-2632
1 test port
2 system relief valve
3 steer relief valve
4 lift relief valve
64
5-12

Valve Coils

How to Test a Coil
A properly functioning coil provides an
electromagnetic force which operates the solenoid
valve. Critical to normal operation is continuity
within the coil. Zero resistance or infinite
resistance indicates the coil has failed.
Since coil resistance is sensitive to temperature,
resistance values outside specification can
produce erratic operation. When coil resistance
decreases below specification, amperage
increases. As resistance rises above specification,
voltage increases.
While valves may operate when coil resistance is
outside specification, maintaining coils within
specification will help ensure proper valve function
over a wide range of operating temperatures.
Note: If the machine has been in operation, allow
the coil to cool at least 3 hours before performing
this test.
1
2
GS
-30m • 32m • 30 • 32 • 46 • 55
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Tag and disconnect the wiring from the coil to
be tested.
Test the coil resistance using a multimeter set
to resistance (W). Refer to the Valve Coil
Resistance Specification table.
Result: If the resistance is not within the
adjusted specification, plus or minus 10%,
replace the coil.
August 2021
Part No. 1309020GT