15 Remove the large platform height sensor
bracket from the number 1 inner arm pivot
bracket.
16 Install the fasteners removed in 14 to the
number 1 inner arm pivot bracket and
chassis.
Tip-over hazard. Failure
to install the fasteners securing
the number 1 inner arm pivot
bracket to the chassis, could
result in the machine tipping
over, causing death or serious
injury.
17 Connect the battery pack to the machine.
18 Turn the key switch to ground controls.
19 Press and hold the ground control scroll up
and scroll down buttons.
20 Pull out the red Emergency Stop button to the
on position at the ground controls.
21 Using the ground control menu buttons,
navigate to Service Override Mode. Select
Service Override Mode.
Note: The machine must be in Service Override
Mode to raise the platform. While in Service
Override Mode, only the GCON will operate with
limited functionality. The platform will raise a
predetermined amount of time and stop.
22 Raise the platform and rotate the safety arm
to the stowed position.
76
23 Fully lower the platform to the stowed
24 Remove the platform. Refer to Repair
25 Remove the cables from the number 4 outer
26 Remove the cables from the number 4 cable
GS
-30m • 32m • 30 • 32 • 46 • 55
position.
Cable bridge and platform height sensor
1 cable bridge 4
2 cable bridge 3
3 cable bridge 2
4 platform height sensor
Procedure, How to Remove the Platform.
arm (index #13) at the ground controls side.
Component damage hazard.
Cables can be damaged if they
are kinked or pinched.
bridge and lay them off to the side.
Component damage hazard.
Cables can be damaged if they
are kinked or pinched.