Outrigger Manifold Components - Gs-3232 - Terex Genie GS-1330m Service And Repair Manual

Hide thumbs Also See for Genie GS-1330m:
Table of Contents

Advertisement

August 2021
5-9
Outrigger Manifold Components – GS-3232
The outrigger function manifold is mounted behind an inspection door, at the battery side of the machine.
Note: 'alpha-numeric' callouts refer to corresponding notes on the electrical schematic.
Index No.
1
Solenoid valve, 3 position 4 way
2
Relief valve, 3500 psi / 241 bar
Coil nut
How to Install a Valve Cartridge
1
Dip the cartridge in clean oil to lube the O-rings.
2
Screw the cartridge in by hand until the top O-ring is met, then torque to specifications.
3
If required, install the valve coil(s) onto the valve stem. Install the coil nut onto the valve stem and
torque to specifications.
Part No. 1309020GT
Description
Schematic Item
GS
-30m • 32m • 30 • 32 • 46 • 55
Function
Outriggers extend /
BA
retract
BB
Outrigger circuit
BA
Service and Repair Manual
Manifolds
Torque
25 ft-lbs / 34 Nm
20 ft-lbs / 27 Nm
4-5 ft-lbs / 5-7 Nm
57