Service and Repair Manual
Scissor Components
87 Attach the strap from an overhead supporting
device to the number 1 inner arm (index #10).
Do not lift it.
88 Remove the upper fasteners securing the
number 1 inner arm pivot bracket to the end
of the chassis. Loosen the lower fasteners.
89 Remove the number 1 inner arm (index #10)
from the machine.
Bodily injury hazard. The
number 1 inner arm may
become unbalanced and fall if
not properly supported when
removed from the machine.
Component damage hazard. Be
sure not to damage the limit
switch or level sensor
components when the number
1 inner arm is removed from the
machine.