Type "FXXX" Faults
DTC
Message on
Number
GCON LCD
F001:SWITCHFAULT
F001:
UP LIMIT1:BAT+
F003:SWITCHFAULT
F003:
DOWN LIMIT1:BAT+
F005:SWITCHFAULT
F005:
POTHOLE:BAT+
F007:SWITCHFAULT
F007:
CHASSISTILT:BAT+
F008:SENSORFAULT
F008:
OVLD XDUCER:BAT+
F009:SENSORFAULT
F009:
OVLD XDUCER:BAT-
F010:SENSORFAULT
F010:
PLAT HEIGHT:BAT+
F011:SENSORFAULT
F011:
PLAT HEIGHT:BAT-
196
Description
Short circuit of the up limit #1 switch
at system startup.
Short circuit of the down limit
#1 switch at system startup.
Short circuit of the pothole limit
#1 switch at system startup.
Short circuit of the chassis digital tilt
switch at system startup.
Short circuit of the Platform Overload
Transducer circuit to battery positive.
Short circuit of the Platform Overload
Transducer circuit to battery negative.
Short circuit of the Platform Height
Sensor circuit to battery positive.
Short circuit of the Platform Height
Sensor circuit to battery negative.
GS
-30m • 32m • 30 • 32 • 46 • 55
Possible Causes
• Short circuit of the up limit switch circuit.
• Up limit #1 switch short circuit.
• GCON ECM.
• Short circuit of the down limit switch circuit.
• Down limit #1 switch short circuit.
• GCON ECM.
• Short circuit of the pothole switch circuit.
• Pothole limit #1 switch short circuit.
• GCON ECM.
• Short circuit of the chassis digital tilt switch circuit.
• Chassis digital tilt switch short circuit.
• GCON ECM.
• Short circuit in the transducer circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the transducer circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the platform height circuit.
• Faulty platform height sensor.
• GCON ECM.
• Short circuit in the platform height circuit.
• Faulty platform height sensor.
• GCON ECM.
August 2021
Failure Mode
Platform up function inhibited.
All functions inhibited except
platform down.
All functions inhibited except
platform down as long as
machine is in the elevated
position. If machine is in
stowed position, all
functionality is resumed.
All functions inhibited except
platform down as long as
machine is in the elevated
position. If machine is in
stowed position, all
functionality is resumed.
All functions inhibited.
All functions inhibited.
All functions inhibited except
platform down as long as
machine is in the elevated
position. If machine is in
stowed position, all
functionality is resumed.
All functions inhibited except
platform down as long as
machine is in the elevated
position. If machine is in
stowed position, all
functionality is resumed.
Part No. 1309020GT