Level Sensors - Terex Genie GS-1330m Service And Repair Manual

Hide thumbs Also See for Genie GS-1330m:
Table of Contents

Advertisement

August 2021
2-6

Level Sensors

The Electronic Control Module (ECM) is
programmed to deactivate the lift and drive
functions and activate an alarm when a signal is
received from the level sensor.
GS-1330m
The tilt alarm sounds when the incline of the
chassis exceeds 1.5° to the side and 2.5° to the
front or rear.
All other models
The tilt alarm sounds when the incline of the
chassis exceeds 1.5° to the side and 3° to the front
or rear.
Part No. 1309020GT
How to Install and Calibrate the
Level Sensor
Note: If you are not installing a new level sensor,
proceed to step 14.
1
Note: Use a digital level to verify the surface is
level.
2
3
4
GS
-30m • 32m • 30 • 32 • 46 • 55
Service and Repair Manual
Ground Controls
Level sensor
1 X axis
2 Y axis
Tip-over hazard. Failure to install
the level sensor as instructed
will compromise machine
stability and cause the machine
to tip over, resulting in death or
serious injury. Do not install the
level sensor other than specified
in this procedure.
Move the machine to an area that has a firm,
level surface and is free of obstructions.
Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position at both ground and platform controls.
Raise the platform 7 to 9 feet / 2,1 to 2,8 m.
Lift the safety arm, move it to the center of the
scissor arm and rotate down to a vertical
position.
35