Terex Genie GS-1330m Service And Repair Manual page 214

Hide thumbs Also See for Genie GS-1330m:
Table of Contents

Advertisement

Service and Repair Manual
Type "CXXX" Faults
Type "CXXX" Faults, (continued)
DTC
Message on
Number
GCON LCD
C029:SYSTEMFAULT
C029:
O/R SENSOR:NOCAL
C053:PCON-GCOM
C053:
SOFTWARE MISMATCH
C055:
C055:DCON ECM
Fault Type 01
C056:DCON ECM
C056:
Fault Type 02
C058:
C058:DCON ECM
Fault Type 04
C059:
C059:DCON ECM
Fault Type 05
C061:
C061:DCON ECM
Fault Type 07
C063:
C063:DCON ECM
Fault Type 09
C064:
C064:DCON ECM
Fault Type 10
C079:MOTOR
C079:
SPEED MONITOR
C080:MOTOR
C080:
TRAVEL MONITOR
C081: MOTOR
C081:
INTERLOCK FAULT
C082:SYSTEMFAULT
C082:
OHL:NoCal
C083:DCON ECM
C083:
SETUP INVALID
Note: An error code C053 will be displayed if an updated PCON is installed on a machine that has not had
the GCON updated. The GCON must be updated, or the original PCON must be installed back on the
machine.
200
Description
Outrigger not calibrated.
Software revisions do not match between the
PCON and GCON.
Hardware failure of drive controller.
Setup initialization failure of the drive
controller at system startup.
Drive controller voltage out of range.
Capacitor charge failure of the drive
controller.
Open circuit of the key switch circuit or
battery positive / negative of the drive
controller.
Communication error of the CAN circuit
between the GCON and the motor controller.
Output error of the thermal sensor circuit of
the motor controller.
Outdoor height limit not calibrated.
GS
-30m • 32m • 30 • 32 • 46 • 55
Possible Causes
• Outrigger not calibrated.
• GCON ECM.
• Short circuit in the safety switch circuit.
• GCON ECM.
• DCON ECM.
• Drive input active at system startup.
• Faulty drive joystick.
• Incorrect software.D14
• DCON ECM.
• Battery charger connected to AC power source.
• Batteries to low.
• DCON ECM.
• Open on B+ or B- to the drive controller.
• DCON ECM.
• Open circuit of the motor controller harness.
• Open circuit to B+ and/or B-.
• Key switch relay power not closed.
• DCON or GCON ECM.
• Open circuit of the motor controller harness.
• DCON or GCON ECM.
• DCON ECM.
• Motor speed detected exceeding the limit set by
the Max Speed Supervision parameter.
• Mis-adjusted Max Speed Supervision
parameters.
• With the vehicle in the stopped state, the motor
frequency and/or phase current detected
exceeding the limit set by the Travel Control
Supervision parameter.
• Mis-adjusted Travel Control Supervision
parameters.
• During an interlock braking event, the motor
speed exceeded he limit set by the Interlock
Braking Supervision parameters.
• OHL not Calibrated.
• Parameter is not modified successfully by
GCON.
August 2021
Failure Mode
All functions operate.
Will not lift above the
down limit switch.
All functions
inhibited.
Performance
reduced or all
functions inhibited.
Performance
reduced or all
functions inhibited.
All functions
inhibited.
All functions
inhibited.
All functions
inhibited.
All functions
inhibited.
All functions
inhibited.
All functions inhibited
except platform
down.
All functions inhibited
except platform
down.
All functions inhibited
except platform
down.
All functions inhibited
except platform
down.
All drive and steer
functions inhibited.
Part No. 1309020GT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents