Type "FXXX" Faults, (continued)
DTC
Message on
Number
GCON LCD
F012:SENSORFAULT
F012:
LEVEL PITCH:BAT+
F013:SENSORFAULT
F013:
LEVEL PITCH:BAT-
F014:SENSORFAULT
F014:
LEVEL ROLL:BAT+
F015:SENSORFAULT
F015:
LEVEL ROLL:BAT-
F016:SENSORFAULT
F016:
LF RIGGER:BAT+
F017:SENSORFAULT
F017:
LF RIGGER:BAT-
F018:SENSORFAULT
F018:
RF RIGGER:BAT+
F019:SENSORFAULT
F019:
RF RIGGER:BAT-
F020:SENSORFAULT
F020:
LR RIGGER:BAT+
F021:SENSORFAULT
F021:
LR RIGGER:BAT-
F022:SENSORFAULT
F022:
RR RIGGER:BAT+
Part No. 1309020GT
Description
Short circuit of the Level Pitch Sensor
circuit to battery positive.
Short circuit of the Level Pitch Sensor
circuit to battery negative.
Short circuit of the Level Roll Sensor
circuit to battery positive.
Short circuit of the Level Roll Sensor
circuit to battery negative.
Short circuit of the Left Front
Outrigger Sensor circuit to battery
positive.
Short circuit of the Left Front
Outrigger Sensor circuit to battery
negative.
Short circuit of the Right Front
Outrigger Sensor circuit to battery
positive.
Short circuit of the Right Front
Outrigger Sensor circuit to battery
negative.
Short circuit of the Left Rear
Outrigger Sensor circuit to battery
positive.
Short circuit of the Left Rear
Outrigger Sensor circuit to battery
negative.
Short circuit of the Right Rear
Outrigger Sensor circuit to battery
positive.
GS
-30m • 32m • 30 • 32 • 46 • 55
Type "FXXX" Faults
Possible Causes
• Short circuit in the level pitch sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the level pitch sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the level roll sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the level roll sensor circuit.
• Faulty level sensor.
• GCON ECM.
• Short circuit in the left front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the left front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the right front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the right front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the left rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the left rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the right rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Service and Repair Manual
Failure Mode
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
Left front outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
Left front outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
Right front outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
Right front outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
Left rear outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
Left rear outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
Right rear outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
197