Coupling/Decoupling Network Cdn 3153-S63.1 - Ametek burst NX8 Quick Start Manual And Safety Instructions

Surge, burst, damped oscillatory, telecom surge generators
Table of Contents

Advertisement

AMETEK CTS
11.11.

Coupling/decoupling network CDN 3153-S63.1

These CDN 3153-S63.1 is fully automatic controlled, featuring plug and play technology - just connect them to the NSG 3150
and they will auto detect and auto configure at system power up, available coupling possibilities will show up in respective test
windows.
All CDN 3153-S63.1 feature:
Manual and programmable control of EUT power ON / OFF
Input phase rotation detection (CDN 3153-S63.1 only)
Thermal monitoring of internal backfilter chokes; in case the EUT current goes up, the integrated fans, which are
still in standby mode and at low EUT currents, will speed up to improve cooling.
In case of intentional or unintentional overloading, the CDN 3153-S63.1 will automatically switch off EUT power, in
order to protect itself (risk of fi re).
All IEC/EN 61000-4-5 couplings up to 15 kV
All ANSI C62.45 couplings with 2 Ω
All ANSI C62.45 couplings with 12 Ω
NSG 3150 on top of CDN 3153-S63.1
Technical specifications:
Voltage ratings:
400 VAC - phase to neutral or phase to ground
690 VAC - phase(s) to phase(s)
up to 1000 VDC - full current range (only with optional INA 3151-63)
EUT Current range
0 A to 63 A
Quick start guide - Single pulse generators
up to 8 kV