Description Of The Menus - Ametek burst NX8 Quick Start Manual And Safety Instructions

Surge, burst, damped oscillatory, telecom surge generators
Table of Contents

Advertisement

AMETEK CTS
10.7.

Description of the menus

The simulator is operated by an easy menu control system. Seven function keys are
available to select parameters and functions. All functions are indicated on the
display; max. 8 lines and 40 characters.
The selected parameter is blinking and can be changed by turning the knob (Inc. /Dec.). The takeover
of the input value occurs after about 500ms encoder downtime. This allows the operator a brief check
of the correct input value.
➔ :
ESC:
EXIT:
EM TEST
OCS 500N6
Damped Oscillatory
V 2.00
Start-up display example OCS 500N6
Page 0
MAIN MENU
F1 Damped Osc. 100kHz
IEC 61000-4-18
F2 Damped Osc. 1MHz
IEC 61000-4-18
F3 Ringwave
100kHz
IEC 61000-4-12
F4 Damped Osc. 100kHz MF IEC 61000-4-10
F5 Damped Osc. 1MHz MF
IEC 61000-4-10
F6 Damped Osc. 1MHz ext.
IEC 60255-26
F7 Service
The digit to be changed can be selected with the cursor (➔).
- Settled values are direct indicated on the screen.
- Status on the bottom lines shows the desired status after pressing the function key.
ESC will take you back to the previous level in the menu and set the displayed values. The
latest settings are stored automatically and will be recalled when the menu is selected again.
The firmware will reset to the main screen.
Oscillatory
Ringwave
SWN: 001234
Page 1
Damp. Osc.100kHz
IEC 61000-4-18
F1 Quick Start
F2 Standard test routines
F3 User test routines
Damped Osc. 1MHz
IEC 61000-4-18
F1 Quick Start
F2 Standard test routines
F3 User test routines
Ringwave
IEC 61000-4-12
F1 Quick Start
F2 Standard test routines
F3 User test routines
Damped Osc. 100Hz MF
IEC 61000-4-10
F1 Quick Start
F2 Standard routines
F3 User test routines
F7 Magnetic field correction factor
Damped Osc. 1MHz
IEC 60255-26
F1 Quick Start
F2 Standard test routines
F3 User test routines
Damped Osc. 1MHz Ext
IEC 60255-
26
F1 Quick Start
F2 Standard test routines
F3 User test routines
Service
F1 Addresses
F2 Setup
F3 Change standard levels
F7
Status
Quick start guide - Single pulse generators
The serial number and the version number SWN are used for
traceability reasons. These numbers are listed in the test reports
and calibration certificates. These numbers also are listed within
the test reports generated by the
AMETEK CTS software ISM IEC.
Page 2
Quick Start
Start
F1 Start
Start the test routine
F2 Change
Change
F3 Continue
Select all parameters
Continue
Continue the test routine
Standard test routines
Standard routines
Preprogrammed test routines as
F1 Common Mode
per standard requirements
F2 Differential Mode
User test routines
User test routines
Preprogrammed test routines for
F1 Synchronous to the mains
evaluation and design support
F2 Random burst release
F3 Change V after T by U
F4 Change polarity after T
Setup Magnetic field
Magnetic field factors
Correction factors for magnetic field
F1 Coil factor Cf [1/m]
antenna
Damped Osc. 1MHz IEC 60255-26
Damped Osc. 1MHz IEC 60255-26
Standard test routines
User test routines
F1 Common Mode 1
F1 Synchronous to the mains
F2 Common Mode 2
F2 Random burst release
F3 Differential Mode
F3 Change V after T by U
F4 Change polarity after T
Setup
Change language
F1 Change language
German or English
F2 LCD backlighting
LCD backlighting
F3 Interfaces
On, Off or Auto
F4 Beeper
Interfaces Select all parameters
F5 Power –on counter
Beeper (on, off)
Power.on counter Display of
Power on time and Testing time
Change standard level
Change standard level
F1 set all parameters acc.to
F1 Level 1
standard
F2 Level 2
F2 Damped Osc. 100kHz
F3 Level 3
F3 Damped Osc. 1MHz
F4 Level 4
F4 Ringwave
100kHz
F5 Damped Osc. 1MHz MF
F6 Coupling Diff / Common
mode
1.00
Page 3
Page 4..x
Standard routines
F1 Level 1
F2 Level 2
F3 Level 3
F7 Manual
User test routines
F1 Start
F2 Change
F3 Continue
Damped Osc. 1MHz IEC 60...
F1 Level 1
F2 Level 2
73 / 88