7.3 Connecting R&S TSMA6B with R&S TSMExxDC +
R&S TSME6
Figure 7-4: R&S TSMA6B + R&S TSMExxDC + R&S TSME6
1
2
3 Aux 1 = DC power: R&S TSMA6B-BP - R&S TSMExxDC
3 Aux 2 = DC power: R&S TSMA6B-BP - R&S TSME6
4
5
6
For the LAN connection between R&S TSMA6B and R&S TSME6, you need LAN
cable of type CAT6.
For the synchronization between R&S TSMA6B and R&S TSMExxDC / R&S TSME6,
you need the synchronization cable R&S TSME6-ZC4, which is required for 3 and
more devices.
For the DC power between R&S TSMA6B-BP and R&S TSME6 / R&S TSMExxDC,
you need need two times the power cable R&S TSMA6-BPPT. Alternatively you can
use the dual power cable R&S TSMA6-B2T. It connects via Aux1 of the R&S TSMA6B
the R&S TSMExxDC and R&S TSME6.
User Manual 4901.4026.02 ─ 01
Connecting R&S TSMA6B with R&S TSMExxDC + R&S TSME6
= LAN connection: R&S TSMA6B - R&S TSME6
= Synchronization: R&S TSMA6B - R&S TSME6 / R&S TSMExxDC
= RF: R&S TSMA6B RF In < 6 GHz
= RF: R&S TSMExxDC RF In 27-30 GHz
= RF: R&S TSMExxDC IF1 - R&S TSME6 RF In
Connecting multiple TSMx devices