Idas Parameters; Table 6-20: Idas Data Channel Properties - Teledyne 200E Instruction Manual

Chemiluminescence nitrogen oxides analyzer
Table of Contents

Advertisement

Model 200E Instruction Manual
Property
NAME
The name of the data channel.
TRIGGERING
The event that triggers the data channel to
EVENT
measure and store its data parameters. See
APPENDIX A-5 for a list of available
triggering events.
NUMBER AND
A User-configurable list of data types to be
LIST OF
recorded in any given channel. See
PARAMETERS
APPENDIX A-5 for a list of available
parameters.
STARTING DATE
The starting date when a channel starts
collecting fata
SAMPLE PERIOD
The amount of time between each data point
that is averaged into one mean reported
every REPORT PERIOD.
REPORT PERIOD
The amount of time between each channel
data point.
NUMBER OF
The number of reports that will be stored in
RECORDS
the data file. Once the specified limit has
been exceeded, the oldest data are over-
written to make space for new data.
RS-232 REPORT
Enables the analyzer to automatically report
channel values to the RS-232 ports.
COMPACT
Enables a compact version of the RS-232
REPORT
reporting with up to five parameters sharing
the same output line.
CHANNEL
Enables or disables the channel. Provides a
ENABLED
convenient means to temporarily disable a
data channel.
CAL HOLD OFF
Disables sampling of data parameters while
instrument is in calibration mode.
Note that - when enabled here - there is
also a length of the DAS HOLD OFF after
calibration mode, which is set in the VARS
menu. (Section 6.5.)

6.10.1.2. iDAS Parameters

Data parameters are types of data that may be measured and stored by the iDAS. For each
T-API analyzer model, the list of available data parameters is different, fully defined and not
customizable. Appendix A-5 lists firmware specific data parameters for the M200E. The
044100102 Rev A

Table 6-20: iDAS Data Channel Properties

Description
Operating Instructions
Default
Setting Range
"NONE"
Up to 6 letters and
digits (more with
APICOM, but only
the first six are
displayed on the
front panel).
ATIMER
Any allowed event.
PMTDET
Any available
concentration,
temperature,
pneumatic or
diagnostic
parameter.
01-JAN-03
Any actual date in
the past or future.
000:01:00
000:00:01 to
366:23:59
(Days:Hours:Minut
es)
000:01:00
000:00:01 to
366:23:59
(Days:Hours:Minut
es)
100
1 to 1 million,
limited by available
storage space.
OFF
OFF or ON
OFF
OFF or ON
ON
OFF or ON
OFF
OFF or ON