Using For Unbalanced Polyphase Output - NF DP Series Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

3. While checking the DC offset of the output voltage, adjust the value in the [DC Adj] item so
that the DC offset gets close to zero.
4. Close the window.
4.15

Using for Unbalanced Polyphase Output

For the polyphase model and polyphase system, you can set the phase voltage and the phase to be
unbalanced. For the polyphase model, the phase can be set to be unbalanced by 35 degrees to the
balanced state. Also for the polyphase system configured by connecting the configurable
single-phase models, the phase can be set to be unbalanced from 0.0 to 359.9 degrees for both L2
phase and L3 phase.
 Operation procedure
1. Press the [Osc] soft-key and select [6: Phase Mode]. The setting window for the phase mode
opens.
DP Series/DP Series Type R

4.15 Using for Unbalanced Polyphase Output

185