4. Advanced Operation
4.24
Power Unit Energization Setting (Using Under the Restricted
Rated Power)
You can enable or disable the energization for each power unit (1.5 kVA per unit) within this
product. If the smaller power is needed for handling the load, you can disable the energization for
some power units to reduce the power consumption of this product.
If there is a power unit on which the energization is disabled, the rated power icon is displayed
inverted. For details on the rated power icon, see 3.2.6 and 5.1.1.
You can disable the energization for the power unit that may have a failure while continuing
operation of this product by using the remaining power units. For details, see 8.1.3.
 Operation procedure
1. Press the MENU key to move to the root menu, then select [System]. The system setting
window opens.
2. Put the cursor on the [Setup] next to the [PU-ON] item, then press the ENTER key. The power
unit energization setting window opens.
208
PROGRAMMABLE AC POWER SOURCE