Setting The Output Voltage (Polyphase Output) - NF DP Series Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

3. Basic Operation
-------- Notes ------------------------------------------------------------------------------------------------------------
 Set the RMS values for the voltages of the sine wave (SIN) and the clipped sine wave (CLP)
and the Peak-to-Peak value for the voltage of the arbitrary waveform (ARB).
-----------------------------------------------------------------------------------------------------------------------------
 Operation procedures for setting the DC voltage
1. Select the [DCV] item and then enter a numeric value. For how to enter values, see 3.3.5.

3.4.5 Setting the Output Voltage (Polyphase Output)

This section describes the operations in the balanced mode in a polyphase model and a polyphase
system. In the balanced mode, the phase voltage and the line voltage are set for all phases at once.
To enter the balanced mode, select the [Osc] soft-key  [6: Phase Mode] to open the phase mode set
window, and select [1:Balance] in the Mode item. For details on the unbalanced mode, see 4.15.
 Operation procedures for setting the phase voltage
1. Check the icon in the output display area (see 5.1) is
or single-phase three-wire system)/
different icon is shown, press the [Osc] soft-key and select [5:Target Phs]  [4:All Phs]. Or
perform the Shortcut operation
62
(three-phase model or three-phase system). If the
+
to switch to [All Phs].
PROGRAMMABLE AC POWER SOURCE
(single-phase three-wire model

Advertisement

Table of Contents
loading

Table of Contents