10. Specifications

10.26.1 CONTROL I/O

When you enabled the external control from the menu, you can control this product by using the
external signal (or non voltage contact). The state output is always on. The detection and state
switching is done at 10 ms-cycle. If the Remote state is achieved by the external interface, a
control input is ignored.
It is not available to use 10.26.2 at the same time.
Control
External control input
input
Input level
Nondestructive maximum input
Input impedance
Control
State
Output level
output
Output impedance
Polarity
Status
Terminal
D-sub 25-pin multi-connector (rear panel, female, M2.6 screw)
*74:
: 0.8 V or lower, High: 2.6 V or higher, the chassis potential.
Low
*75:
Sequence start and stop of the control input are effective for the Simulation as well. Also, step
sync output 1 and 2 of the control output are effective for the Simulation as well.
*76:
The memory recall input of the control input recalls the setting memory for the Normal
(Continuous), the Sequence Memory for the Sequence, and the Simulation Memory for the
Simulation. For the Sequence and Simulation, the compile data is also included.
*77:
Low: 0.4 V or lower, High: 2.7 V or higher, the chassis potential.
*78:
Polarity reverse (collective) is available only for the state with *.
296
Item
Output Off
Output On
Sequence start/resume
Stop of sequence
Sequence is in the Hold status
Sequence branch 1
Sequence branch 2
Memory recall (+ compile)
Memory specification 1
Memory specification 2
Clear the current peak-hold value Falling Clear
Power On/Off
Output On/Off*
Protection operation*
Limiter operation*
AGC/Autocal setting state*
Software busy*
Output range
Sequence operation
Step sync 1
Sequence operation
Step sync 2
Trigger
Description
Enabled or Disabled
TTL
+10 V / 5 V
Pull-up to +5 V via 47 k
Falling Off
Falling On
*75 Falling Start
*75 Falling Stop
Falling Hold
Falling Branch start
Falling Branch start
*76 Falling Recall
Specify 0 to 3
(Equivalent to memory 1 to 4, respectively)
TTL
220 
*78 Positive or Negative
Low: Off, High: On
Low: On, High: Off (Negative)
Low: Off, High: On (Positive)
Low: Active, High: None
Low: None, High: Active (Positive)
Low: Active, High: None
Low: None, High: Active (Positive)
Low: On, High: Off (Negative)
Low: Off, High: On (Positive)
Low: Busy, High: Ready (Negative)
Low: Ready, High: Busy (Positive)
Low: 200 V, High: 100 V
*75
High level or Low level
*75
Positive
or Negative
PROGRAMMABLE AC POWER SOURCE
Factory
default
*74
*77
Negative
(Negative)
(Negative)