3.4.10 Switching the Display Format (RMS/AVG/Peak) of the Measured Value

You can switch the display format of the measured value (RMS/AVG/Peak) for the output voltage
and output current. The items which are displayed in each measuring mode are shown in Table 3-12.
Table 3-12 The Measuring Mode for the Measured Values of the Output Voltage and
Measuring
mode
RMS
AVG
Peak
 Operation procedures using soft-keys
1. Press the [Measure] soft-key and select [2:Measure]. The [Measure] window opens.
2. Select the [Type] item. In the displayed selection box, select the desired measuring mode.
3. Close the window. For how to close the window, see 3.3.4.
68
Output Current
Items to be Displayed
(Output Voltage, Output Current)
V, I, Ipk-Hold
Vavg, Iavg, Ipk-Hold
Vmax, Vmin, Imax, Imin, Ipk-Hold