4. Advanced Operation
3. In the [Contrast] item, set the contrast value.
4. Close the window.
-------- Notes ------------------------------------------------------------------------------------------------------------
The L2 and L3 cabinets in a polyphase system accept the Shortcut operation
for this function. In this case, if other window such as the Emission CO
being displayed, that window closes and the window for adjusting LCD opens only on the
cabinet on which you performed the operation. To open the previous window after adjusting
LCD, close the window displayed in the L1 cabinet and reopen it.
-----------------------------------------------------------------------------------------------------------------------------
4.28
Restoring to the Factory Default Setting (Reset)
If you reset this product, the setting items marked with in Table 4-16 are restored to the factory
default settings. Ensure that you reset this product in the output off state.
Setting Item
Output on/off
Output range
AC/DC mode
Signal source
External synchronization signal (LINE
or EXT)
AC voltage setting
Frequency
Output waveform
Output on phase
Output off phase
Phase voltage/Line voltage setting
selection
Line voltage setting
212
Table 4-16 Setting Items to be Reset
Reset
×
Calculator window is
2
Factory default setting
Off
100 V range
AC mode
INT
LINE
0 V
50 Hz
Sine wave
0.0 deg
Enabled, 0.0 deg
Phase voltage
0 V
PROGRAMMABLE AC POWER SOURCE
+