Current Limiter - NF DP Series Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

10. Specifications

10.13 Current Limiter

This controls the output voltage for the output current to be within the limiter setting value when
the peak value or RMS exceeds it. The output can be configured to be turned off when the limited
state continues over the specified time.
In the polyphase model, polyphase system, and polyphase output of the Multi-phase model, the
settings are made for the phase current and common to all the phases.
Peak current limiter
DP series
DP series Type R
Positive
Setting Range
current
(Peak value)
*55
Factory
default
Negative
Setting Range
current
(Peak value)
*55
Factory
default
Resolution
Limiter operation
DP series
DP series Type R
Positive
Setting Range
current
(Peak value)
*55
Factory
default
Negative
Setting Range
current
(Peak value)
*55
Factory
default
Resolution
Limiter operation
*55:
If you increased or decreased the number of units by the power unit energization setting, the
factory default setting corresponding to the capacity is used. (Example: In the case that only 3
units operate in 6 kVA model, the factory default setting of 4.5 kVA model is used.)
284
Single-phase model, Polyphase model, Multi-phase model
015S,030D,045T,
030S,060D,090T,
045M
090M
(polyphase
output)
015RS,030RD,
030RS,060RD,
045RT
+7.5 A to +63.0 A
+15.0 A to +126.0 A
/ +3.7 A to +31.5 A
/ +7.5 A to +63.0 A
+63.0 A / +31.5 A
+126.0 A / +63.0 A
63.0 A to 7.5 A /
126.0 A to 15.0 A /
31.5 A to 3.7 A
63.0 A to 7.5 A
63.0 A / 31.5 A
126.0 A / 63.0 A
0.1 A
Select whether to recover automatically (continuous) or turn the output off
when the limited state continues over the specified time (1 s to 10 s,
resolution 1 s).
Factory default setting is output OFF when the limit state continues for 10 s.
Single-phase model and Single-phase output of Multi-phase model
075S
090S, 090M
075RS
+37.5 A to +315.0 A
+45.0 A to +378.0 A
/+18.7 A to +157.5 A
/+22.5 A to +189.0 A
+315.0 A / +157.5 A
+378.0 A / +189.0 A
315.0 A to 37.5 A /
378.0 A to 45.0 A /
157.5 A to 18.7 A
189.0 A to 22.5 A
315.0 A / 157.5 A
378.0 A / 189.0 A
0.1 A
Select whether to recover automatically (continuous) or turn the output off
when the limited state continues over the specified time (1 s to 10 s,
resolution 1 s).
Factory default setting is output OFF when the limit state continues for 10 s.
045S, 090D,
045M
(polyphase
(single-phase
output)
output)
045RS,090RD
090RT
+22.5 A to +189.0 A
/ +11.2 A to +94.5 A
+189.0 A / +94.5 A
189.0 A to 22.5 A /
94.5 A to 11.2 A
189.0 A / 94.5 A
105S
090RS
+52.5 A to +441.0 A
/+26.2 A to +220.5 A
+441.0 A / +220.5 A
441.0 A to 52.5 A /
220.5 A to 26.2 A
441.0 A / 220.5 A
PROGRAMMABLE AC POWER SOURCE
060S, 120D
060RS
+30.0 A to +252.0 A
/+15.0 A to +126.0 A
+252.0 A / +126.0 A
252.0 A to 30.0 A /
126.0 A to 15.0 A
252.0 A / 126.0 A
120S
+60.0 A to +504.0 A
/+30.0 A to +252.0 A
+504.0 A / +252.0 A
504.0 A to 60.0 A /
252.0 A to 30.0 A
504.0 A / 252.0 A