Parameters Of Sequence Function; Table 4-2 Parameters Of Sequence Function - NF DP Series Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

4.2.2 Parameters of Sequence Function

Table 4-2 shows the parameters of Sequence function. The common parameters are common to one
sequence. In Sequence function, signal source is fixed to INT. In each step, set the step-control
parameter and the intra-Step parameter. As for intra-Step parameter, the item and range that can be
set differ depending on the output range (100 V/200 V range) and output mode
(AC-INT/ACDC-INT/DC-INT) as in the case of Continuous function. This section describes
intra-Step parameters and step-control parameters separately.
Common
parameter
Output range
AC/DC mode
 Frequency (Freq), waveform (Wave), phase angle (Phase), AC phase voltage (ACV), DC
voltage (DCV)
The setting for the output of each step. In polyphase model/polyphase system, AC phase voltage and
phase angle can be set for each phase. In the phase angle, set the phase difference with the L1 phase.
Phase angle can also be set per step. The phase angle of L1 phase cannot be set, and is fixed as 0
deg.
 Step Time (Step Time)
Set the output time of that step. Unit can be selected from [s] or [ms].
 Jump-to step (Jump To)
When selected, the destination step of the jump at the end of the step can be specified. By specifying
the Jump count ([Jump Cnt]), you can set up a loop to repeat the same step. After jumping for the
times specified for one sequence, the action at the end of step follows the step termination setting.
If Jump-to is set to off, the action at the end of step follows the step termination setting.
-------- Notes ------------------------------------------------------------------------------------------------------------
 When the step termination is set as [Hold], the hold status is enabled before the jump.
-----------------------------------------------------------------------------------------------------------------------------
DP Series/DP Series Type R

Table 4-2 Parameters of Sequence Function

Step-control parameter
Step Time
Jump-to step
Jump count (1 to 9999, or infinite)
Branch step
Step termination
Step sync code output (2bit)
Start Phase
Stop Phase
Trigger output
4.2 Using Sequence Function
Intra-Step parameter
Frequency
Waveform
Phase angle
AC phase voltage
DC voltage
89