Error Messages And Error Handling; Error Message Screen; If An Error Message Is Displayed; Figure 8-1 Error Message Screen Example - NF DP Series Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

8. Troubleshooting
8.1

Error Messages and Error Handling

8.1.1 Error Message Screen

An error message screen opens as shown in Figure 8–1, for example, in case that the protection
function is activated. The description of each item is shown in Table 8-1.
a
b
c
d
Symbol
Name
a
Screen title
b
Protection type
c
Error ID
d
Message
e
Press Enter Key
f
Soft-key
[PU-ON]

8.1.2 If An Error Message is Displayed

If an error message is displayed, handle it by the following procedure. When the error occurs
repeatedly, handle it according to 8.1.3.
 Handling procedure
1. Check on the error content and remove the reason of the error. For each message and its
handling method, see 8.1.5.
2. When the protection type says System Locked, cycle the power of the product.
3. When the protection type says Output OFF, press the ENTER key. The error message
disappears.
4. Now the product is available.
248

Figure 8-1 Error Message Screen Example

Table 8-1 Description of the Error Message Screen

System Lock: An error whose protection type is System
Lock
Warning: An error whose protection type is Output Off
System Locked: System Lock
Output OFF: Output Off
The number to identify an error.
Describes the error details.
Displayed for an error whose protection type is Output
Off.
Displayed for an error that occurred on the power unit.
This key opens the power unit energization setting
window, enabling you to disable the energization of the
power unit that repeatedly generates the error.
a
b
c
d
Description
PROGRAMMABLE AC POWER SOURCE
e
f
Refer to
8.1.4
8.1.4
8.1.5
8.1.5
8.1.2
8.1.3

Advertisement

Table of Contents
loading

Table of Contents