4. Advanced Operation

4.3.2 Simulation Function Parameters

Table 4-4 shows the parameters of Simulation function. The common parameters are common to one
simulation. In the Simulation function, the signal source is fixed to INT sine wave and the ACDC
mode to ACDC mode. When in polyphase, the balanced mode is always used. In each step, set the
step-control parameter and the intra-Step parameter. As for intra-Step parameter, the range that can
be set differ depending on the output range (100 V/200 V range) as in the case of Continuous
function.
Common
parameter
Output range
AC/DC mode
(Fixed to ACDC)
Waveform
(Fixed to sine
wave)
 Relationship between each step and settable Step parameters
V1, F1
Normal1
Trigger output
トリガ出力
Sync output
同期出力
120

Table 4-4 Simulation Function Parameters

Step-control parameter
Step Time
Start Phase
Stop Phase
Trigger output
Step sync code output (2bit)
Repeat count (1 to 9999 or infinite)
Trans1
移行1
定常1
T1
T2
S1
S2

Figure 4-11 Simulation Function Steps

Frequency
AC voltage
V3, F3
Abnormal
Trans2
異常
移行2
T3
T4
S3
S4
PROGRAMMABLE AC POWER SOURCE
Intra-Step parameter
V1, F1
Voltage and
電圧・周波数は
正常1と同じ
frequency are
same as
Normal 1
Normal2
定常2
T5
S5