Figure 4-1 Step-Control Parameters And Intra-Step Parameters - NF DP Series Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

 Keep a sequence setting
The sequence setting is kept per AC/DC mode. Every time AC/DC mode is changed, the sequence
setting that is already kept is loaded. The sequence setting is cleared when the power is turned off.
To save the setting, you need to save it in internal memory or USB memory (see 4.9).
 Step
One sequence consists of a series of two or more steps. To use Sequence function, first set each step.
 Step-control Parameters and intra-Step Parameters
There are the following two major types of parameters in Sequence function:
 Step-control parameter
Parameter to control the flow between two or more steps. This defines duration of each step
and the next step to transition. Settings of step synchronous code and trigger output are
included in step-control parameter for convenience.
 Intra-Step parameter
Parameter to define output state in each step. This defines basic parameters such as a
waveform, frequency, and how they are changed in the step.
Icon
Step number

Figure 4-1 Step-control Parameters and intra-Step Parameters

 Step No. 0
Step No. 0 is assigned to the stand-by state before the sequence starts. If the terminal specification
of the step other than No. 0 is End, the execution transitions to step No. 0 and enters into the
stand-by state. Step Time and the Step Behavior setting of No. 0 specifies the action to transit to No.
0 at the end of a sequence.
DP Series/DP Series Type R
4.2 Using Sequence Function
Step-control parameter
Intra-Step parameter
87