Using Control I/O - NF DP Series Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

4.18.1 Using CONTROL I/O

You can control the output on/off and the starting/stopping of Sequence by inputting the logic signal
or the non voltage contact signal. You can also get the product state by using the logic signal. The
polarity of state output can be switched. The connector to be used is DBLC-J25SAF-10L9E (D-sub,
25-pin, M2.6 mm screw) manufactured by JAE. For the specification of I/O signals, see 10.26, and
for the pin assignment of the CONTROL I/O connector, see Table 4-12. For the multi-phase model
only, attach the provided ferrite core (large) to the product side of the cable connected to the
connector. If the cable is thin, bind the cable and ferrite core with the provided cable tie.
-------- Notes ------------------------------------------------------------------------------------------------------------
 We recommend that when the external control function is not used, the function is set to
[1: Disable] to avoid malfunctioning due to any exogenous noise.
 It is not able to use CONTROL I/O with control of DIP at the same time.
 The external control input signal is ignored when the product is remote controlled via the
communication interface.
 The memory 1 and 2 inputs are the inputs for specifying the memory number. For No. 1 to No.
4 memory, specify the 2 bit memory number of the Basic Setting Memory in the Continuous
function, or of the Sequence Memory in the Sequence function, or of the Simulation Memory
in the Simulation function.
 When the memory recall input is changed from high to low, this loads the data of the Basic
Setting Memory in the Continuous function, or of the Sequence Memory in the Sequence
function, or of the Simulation Memory in the Simulation function which has the number
specified by the memory 1 and 2 inputs. For the Sequence and Simulation function, the
compile is also performed.
-----------------------------------------------------------------------------------------------------------------------------
DP Series/DP Series Type R
4.18 Control Using External Control Function
Cable tie
Ferrite core (large)
CONTROL I/O cable
193