Setting Range Limit Function - NF DP Series Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

10. Specifications

10.14 Setting Range Limit Function

This is the limit function for the setting of the internal signal source. It works when the signal
source is INT, VCA (frequency setting limit only), SYNC (voltage setting limit only), or ADD
(internal signal source only). The limitation does not work for the Sequence and Simulation. It
does not also work for the external signal source of EXT and ADD.
In the polyphase model, polyphase system, and polyphase output of the Multi-phase model, the
setting is common to all the phases.
Voltage setting limit 1 (in the AC mode, and sine wave or clipped sine wave is selected)
Setting range
(effective value)
Factory default
Resolution
*58:
The line voltage setting is available only when the output voltage setting is set as the line
voltage and sine wave is selected in the balanced mode of the polyphase model, polyphase
system, and polyphase output of the Multi-phase model.
Voltage setting limit 2 (other than Voltage setting limit 1, phase voltage setting only) *59
Positive
Setting Range
(Peak value)
voltage
Factory
default
Negative
Setting Range
(Peak value)
voltage
Factory
default
Resolution
*59:
The limitation is applied to the additional values of the AC voltage setting (recalculated to a
peak value) and the DC voltage setting.
Frequency setting limit (the lower limit  the upper limit) *60
Upper limit
Setting Range
Factory
default
Lower
Setting Range
limit
Factory
default
Resolution
*60:
In the AC mode, the setting range is 40.00 Hz to 550.00 Hz.
286
Phase voltage setting
*58
0.1 V to 160.0 V / 0.1 V to 320.0 V
Line voltage setting (single-phase three-wire)
0.2 V to 320.0 V / 0.2 V to 640.0 V
Line voltage setting (three-phase four-wire)
0.2 V to 277.2 V / 0.2 V to 554.2 V
Phase voltage setting, 160.0 V / 320.0 V
Phase voltage setting: 0.1 V, line voltage setting: 0.2 V
+0.1 V to +227.0 V / +0.1 V to +454.0 V
+227.0 V / +454.0 V
227.0 V to 0.1 V / 454.0 V to 0.1 V
227.0 V / 454.0 V
0.1 V
1.00 Hz (AC mode : 40.00 Hz) to 550.00 Hz
550.00 Hz
1.00 Hz (AC mode : 40.00 Hz) to 550.00 Hz
1.00 Hz (AC mode : 40.00 Hz)
0.01 Hz
All models
All models
All models