BATTERY/CHARGING SYSTEM
Measure the specific gravity of each cell with hidrometer.
Fully charged:
1.27-1.29
Need charging:
Below 1.23
NOTE
• If the difference in specific gravity between cells exceeds
0.01, re-charge the battery. If the difference in specific
gravity is excessive, replace the battery.
Make sure that terminal conditions are not loose. If corrosion is
evident, wash rust with warm water and use a wire brush to
remove completely.
CHARGING
Connect the charger positive (+) cable to the battery positive (+)
terminal.
Connect the charger negative (-) cable to the battery negative (-)
terminal.
Charging current
Standard
0.4 A
Maximum
4.0 A
After charging, recheck the battery specific gravity and recharge
the battery if necessary.
Replace the battery with a new one if the battery specific gravity
below 1.23.
t
• The battery gives of explosive gases; keep sparks, flames,
and cigarettes away. Provide adequate ventilation when
charging or using the battery in an enclosed space.
1 5 -4
Charging time
5 hours
30 minutes
(1) BATTERY
XL2 0 0

Hide quick links: