Siemens SIMATIC RF300 System Manual page 91

Hide thumbs Also See for SIMATIC RF300:

Advertisement

Transponder flush-mounted in metal; minimum distance to the reader is 15 mm
2)
With ISO transponders (MDS D)
Table 4-61
Transponder
MDS D100
MDS D124
MDS D126
MDS D139
MDS D200
MDS D324
MDS D339
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
Reduction of field data due to metal, range as %: Transponder and RF360R
1)
Without metal
On metal; distance 20 mm
Flush-mounted in metal;
circumferential distance
20 mm
4)
Without metal
1)
On metal; distance 15 mm
Flush-mounted in metal;
circumferential distance
25 mm
2)
Without metal
1)
On metal; distance 25 mm
Flush-mounted in metal;
circumferential distance 50 mm
Without metal
1)
On metal; distance 30 mm
Flush-mounted in metal;
circumferential distance
100 mm
4)
Without metal
1)
On metal; distance 20 mm
Flush-mounted in metal;
circumferential distance
20 mm
3)
Without metal
1)
On metal; distance 15 mm
Flush-mounted in metal;
circumferential distance
25 mm
2)
Without metal
On metal; distance 30 mm
Flush-mounted in metal;
circumferential distance
100 mm
4)
Planning the RF300 system
4.3 Installation guidelines
Reader RF360R
Without metal
On metal
100
90
70
65
60
45
100
95
85
85
80
80
100
90
80
80
75
75
100
95
100
90
100
90
100
95
90
85
75
50
100
95
90
85
80
80
100
95
100
90
100
90
Flush-mounted
in metal
(20 mm all-
round)
75
60
45
80
75
45
85
70
65
80
75
75
90
80
65
80
75
60
80
75
75
91