Download Print this page

Siemens SIMATIC RF300 System Manual page 433

Hide thumbs Also See for SIMATIC RF300:

Advertisement

Explanations:
• "LFD" is a measured value for the field strength that is determined in the transponder. The
lower the value, the higher the field strength.
• "FZP" counts interference pulses when communication with a transponder is not taking place
(e.g. electromagnetic interference caused by contactors, motors, etc.). Counter values can
also be generated when a transponder is located at the edge of the field even when there is
no external interference.
• "FZA" counts errors that can occur during reader-to-transponder communication. This can be
caused by unsuitable reader/transponder positioning (e.g. transponder on field boundary or
several transponders in antenna field) or external electromagnetic interference.
• "ANWZ" is the value for the time that the transponder remains in the antenna field before the
"Tag-Status" (MDS STATUS) with attribute "0x82" (mode 02) is executed. A time step is 10 ms.
The maximum time that can be recorded is therefore 2.5 s.
Attribute "0x83" (mode 03), corresponds to UDT 230
Name
Type
UID
array[1...8] byte
MDS_type
byte
IC_version
byte
size
word
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
Possible Values (hex)
0000000000000000 ...
FFFFFFFFFFFFFFFF
0x00
0x03
0x04
0x05
0x06
0x07
0x08
0x11
0x12
0x13
0x14
0x21
0x22
0x23
0x41
0x42
0x43
0x44
0x00 ... 0xFF
0x00 ... 0xFFFF
10.2 Diagnostics functions - STEP 7
Comment
Unique identifier
=8 byte UID, MSB first
Transponder type (vendor, identification)
= ISO 15693 general
= ISO 15693 (MDS D3xx; Infineon)
= ISO 15693 (MDS D4xx; Fujitsu - 2 kB)
= ISO 15693 (MDS D1xx; NXP)
= ISO 15693 (MDS D2xx; TI)
= ISO 15693 (MDS D261; STM)
= ISO 15693 (MDS D5xx; Fujitsu - 8 kB)
= RF300 transponder (0 kB)
= RF300 transponder (8 kB)
= RF300 transponder (32 kB)
= RF300 transponder (64 kB)
= ISO 14443 (MDS E; NXP, 1 kB)
= ISO 14443 (MDS E; Infineon, 1 kB)
= ISO 14443 (MDS E; NXP, 4 kB)
= P2P RF310R, 2nd generation
= P2P RF340R, 2nd generation
= P2P RF350R, 2nd generation
= P2P RF380R, 2nd generation
Chip version
Memory size in bytes
depending on transponder type, e.g. MDS D3xx: 992
bytes
System diagnostics